ANALYSIS OF THE HEATING CAPACITY OF ELECTRICALLY HEATED WINDOWS


  • P.G. Krukovskyi Institute of Engineering Thermophysics of NAS of Ukraine
  • D.A. Smolchenko Institute of Engineering Thermophysics of NAS of Ukraine
  • G.P. Krukovskyi Institute of Engineering Thermophysics of NAS of Ukraine
  • А.І. Deineko Institute of Engineering Thermophysics of NAS of Ukraine
Keywords: electrically heated window, heating capacity, energy efficiency, room heat exchange, modeling, low emission flooring, room heating.

Abstract

Electric window heating has been used for some time in Europe and the Americas, but in Ukraine it only enters the market as an independent heating device and raises the question of its heating capacity in winter and the benefits of using them. There are several works in this field that determine the efficiency and contribution to the energy needs of an electric-heated window house, but it is necessary to answer more specifically the question of the heating capacity of such windows as a single heating system, for example rooms of certain sizes.In the work present the design, thermophysical processes occurring in such windows and, by computer simulation of the thermal state of the window with the selected typical room, the results of the study of the heating capacity of the windows, depending on the relative glazing area to the total area of the outer enclosure and the ambient temperature conditions not exceeding the maximum heat emission 450 /  and temperature 45 °С on the inner glass of the double-glazed window. the presented thermal model of the window with the room is implemented as a computer program with the possibility of a detailed analysis of the heating capacity of the window, depending on the parameters of the room and the outside temperature, as well as optimization of operational parameters to maintain comfortable conditions.

References

1. J Kurnitski. Efficiency of electrically heated windows. International Conference: Indoor Air Quality and Climate. Held in Monterey. California. June 30-July 5. 2002.
2. Jarek Kurnitski, Juha Jokisalo, Jari Palonen, Kai Jokiranta, Olli Seppänen. Efficiency of electrically heated windows. Energy and Buildings. 2004. Vol. 36, №. 10. P.1003-1010
3. Alain Moreau, Simon Sansregret, Michael Fournier. Modeling and Study of the Impacts of Electrically Heated Windows on the Energy Needs of Buildings. Conference: WSEAS International Conference on heat transfer, thermal engineering and environment. At Rhodes. Greece. August 2008.
4. Alain Moreau, Manuelle Coullin, Guillaume Delamarre, François Laurencelle. Simulation et validation expérimentale d’un modèle de fenêtre chauffante. Conference: Colloque International Francophone d'Énergétique et Mécanique. At Comores. May. 2014.
5. Electrically Heated glass. Finnglass: web site URL: https://www.finnglass.com/products/electrically-heated-glass (date of appeal: 09.01.2020).
6. Xomchenko А.V. Issledovanie svojstv elektroobogrevaemyh steklopaketov [The study of the properties of electric double-glazed windows]. Vestnik Belrusko-Rosijskogo universiteta [Bulletin of the Belarusian-Russian University]. 2016. №3. С. 152-157. (Rus.)
7. Flownex simulation environment: web site URL: https://www.flownex.com/ (date of appeal: 13.01.2020).
8. Bohoslovskyi V. N Teplofizicheskie osnovy otopleniya, ventilyacii i kondicionirovaniâ vozduha [Thermophysical basics of heating, ventilation and air conditioning.]. Stroitelnaya teplofizika [Building Thermophysics]. 1982. №2. (Rus.).

Abstract views: 73
PDF Downloads: 39
Published
2021-12-20
How to Cite
Krukovskyi, P., Smolchenko, D., Krukovskyi, G., & DeinekoА. (2021). ANALYSIS OF THE HEATING CAPACITY OF ELECTRICALLY HEATED WINDOWS. Thermophysics and Thermal Power Engineering, 43(4), 62-67. https://doi.org/https://doi.org/10.31472/ttpe.4.2021.7
Section
District and Industrial Heat Power, Renewable Energy Systems, Energy Efficiency